TR-7W Series - Network-Dedicated Temp/Humidity Data Logger

Standard Kit
  • AC Adaptor(*1)
    AD-0605 or
    AC Adaptor(*1)<br />AD-0605 or
  • AC Adaptor(*1)
    AD-05C1
    AC Adaptor(*1)<br />AD-05C1
  • Lithium Battery(Coin type)
    Lithium Battery(Coin type)
  • LAN Cable(LN-20W):2m
    LAN Cable(LN-20W):2m
  • Software CD
    Software CD
  • Manual(Warranty)
    Manual(Warranty)
(*1)Either by region are packaged adaptor. For more information, please contact our dealer.
TR-71W
Standard Kit + TR-0106(x2)
TR-71W
TR-72W
Standard Kit + TR-3110 (x1) / Sensor Response Time: About 7 minutes (Time to 90 % of total humidity)
TR-72W
Setup
TR-7W Series setup
Temperature Sensors for TR-71W/72W
Possible Measurement Range -40 to 110°C Sensor Temperature Durability: -50 to 115°C
Measurement Accuracy: Average ±0.3°C(-20 to 80°C) Average±0.5°C(-40 to -20°C / 80 to 110°C)
※Only stainless section is water resistant.
Materials: (1)Thermistor, (2)TPE resin-shielded sensor, (3)TPE resin-shielded wire, (4)M3Screw Hole, (5)Compaction Tube, (6)Stainless Pipe (SUS304)
TR-0106
TPE resin-shielded sensPor
Cable Length: 0.6m
Thermal-Constant Time: In the Air: Approx. 75 Sec.
TR-0106
Unit: mm
TR-0206
Stainless Protection Sensor
Cable Length:0.6m
Thermal-Constant Time: In the Air: Approx. 75 Sec
TR-0206
Unit: mm
TR-0306
Stainless Protection Sensor
Cable Length:0.6m
Thermal-Constant Time: In agitated water: Approx. 18 Sec.
TR-0306
Unit: mm
TR-0406
Stainless Protection Sensor
Cable Length:0.6m
Thermal-Constant Time: In agitated water: Approx. 20 Sec.
TR-0406
Unit: mm
TR-0506
Stainless Protection Sensor
Cable Lenth:0.6m
Thermal-Constant Time: In agitated water: Approx. 20 Sec.
TR-0506
Unit: mm
TR-0706
Stainless Protection Sensor
Cable Length:0.6m
Thermal-Constant Time: In agitated water: Approx. 18 Sec.
TR-0706
Unit: mm
Temperature Sensors for TR-71W
Possible Measurement Range: -60 to 155°C / Sensor Temperature Durability: -70 to 180°C
Water Resistant Ability: Splash proof / Measurement Accuracy: Average ±0.5°C(-40 to 80°C)
Average±1.0°C(-60 to -40°C / 80 to 100°C) Average ±2.0°C (100 to 155°C)
Materials: (1)Thermistor, (2)Stainless Pipe (SUS316), (3)Fluoropolymer-Coated Compaction Tube, (4)Fluoropolymer-Coated Electrical Wire
TR-1106
Fluoropolymer-Coated Sensor
Cable Length :0.6m
Thermal-Constant Time:
In the Air Approx. 30 Sec.
In agitated water: Approx. 4 Sec.
TR-1106
Unit: mm
TR-1220
Stainless Protection Sensor
Cable Length: 2m
Thermal-Constant Time:
In the Air: Approx. 36 Sec
In agitated water: Approx. 7 Sec.
TR-1220
Unit: mm
TR-1320
Stainless Protection Sensor
Cable Length: 2m
Thermal-Constant Time:
In the Air: Approx. 12 Sec
In agitated water: Approx. 2 Sec.
TR-1320
Unit: mm
Sensor Extension Cable (Temp Sensors Only)
Can not be used with Temperature / Humidity Sensors.
Only one extension cable can be used with each sensor.
When using an extension cable there will be a gap of +0.3°C at normal temperature and at -50°C, a gap of +0.5°C may occur.
Materials: (1)Vinyl Coated Electrical Wire
TR-1C30
Cable Length:3m
TR-1C30
Unit: mm
Humidity and Temperature Sensors for TR-72W
Possible Temperature Measurement Range :0 to 50°C / Possible Humidity Measurement Range :10 to 95%RH
Sensor Temperature Durability :-10 to 55°C / Humidity Measurement Accuracy :±5%RH (at 25°C 50%RH)
Operational conditions :Without dew condensation, water leakage or effect from corrosive gas or organic solvents.

The service life of humidity sensors can vary greatly depending on operating environment. Periodic calibration may be required.
Materials: (1)Temperature / Humidity Sensor, (2)Polypropylene resin
TR-3110
Humidity and Temperature Sensor
Sensor Response Time: About 7 minutes (Time to 90 % of total humidity)
TR-3110
Unit: mm
AC Adaptor
AD-05C1
Cable Length:1.60m
Input:AC100-240V
Output:DC 5V 2A
Frequency:50 / 60Hz
Plug Figure: C

AD-05C1
AD-0605
Cable Length:1.85m
Input:AC 100V(90-132V)
Output:DC 5V 2A
Frequency:50 / 60Hz
Plug Figure: A
AD-0605