Standard Kit
-
- Manual

-
- Battery

-
- O-ring

-
- Screws

-
- Silica gel

RTR-51/51A/51L/51AL
Standard Kit only
RTR-52/52A/52L/52AL
Standard Kit + TR-5106
RTR-52Pt/52PtL
Standard Kit + RTR-05P1
RTR-53/53A/53L/53AL
Standard Kit + TR-3310 / Sensor Response Time: About 7 minutes (Time to 90 % of total humidity)
RVR-52A/52AL
Standard Kit + RPR-7101
Setup
Optional Temperature Sensors for RTR-52/52A
Materials: (1)Thermistor, (2)Stainless pipe (SUS316), (3)Fluoropolymer-Coated Compaction Tube, (4)Fluoropolymer-Coated Electrical Wire, (5)Fluoropolymer-Coated Mold
TR-5106
Fluoropolymer-Coated Sensor
Cable Length: 0.6m (24in)
Thermal Time Constant:
Approx. 30 Sec. (in air)
Approx. 4 Sec. (in agitated water)
Unit: mm
TR-5101
Fluoropolymer-Coated Sensor
Cable Length: 45mm (1.8in)
Thermal Time Constant:
Approx. 30 Sec. (in air)
Unit: mm
TR-5220
Stainless Protection Sensor
Cable Length: 2.0m (80in)
Thermal Time Constant:
Approx. 36 Sec. (in air)
Approx. 7 Sec. (in agitated water)
Unit: mm
TR-5320
Stainless Protection Sensor
Cable Length: 2.0m (80in)
Thermal Time Constant:
Approx. 12 Sec. (in air)
Approx. 2 Sec. (in agitated water)
Unit: mm
TR-5420
Stainless Protection Sensor
Cable Length: 2.0m (80in)
Thermal Time Constant:
Approx. 12 Sec. (in air)
Approx. 2 Sec. (in agitated water)
Unit: mm
TR-5530
Water Immersible Sensor
Cable Length: 3.0m (120in)
Thermal Time Constant:
Approx. 120 Sec. (in air)
Approx. 6 Sec. (in agitated water)
Unit: mm
RTR-52Pt Optional Sensor
Materials: (1)Vinyl, (2)Vinyl Coated Electrical Wire
RTR-05P1
Sensor Adaptor Cable
Unit: mm
M12 (IEC 61076-2-101) Type Sensor Connector Cable for RTR-52Pt
Wide range of mounting tools available...
Please see this website for details.
Italcoppie sensori s.r.
http://www.italcoppie.it/
Unit: mm
RTR-53/53A Optional Sensor
Materials: (1)Temperature/Humidity sensor, (2)Polypropylene resin, (3)Vinyl Coated Electrical Wire
TR-3310
Temp / Humidity Sensor
Sensor Response Time: About 7 minutes (Time to 90 % of total humidity)
Unit: mm
RVR-52 Optional Input Cables ( for Europe only )
Materials: (1)Clip, (2)M3.5 Crimp Terminal, (3)Vinyl Coated Electrical Wire, (4)Connector
RVR-7101
Input Cable
Unit: mm
RVR-7102
Input Cable
Unit: mm
RVR-7103
4-20mA Probe
Maximum Current Input: MAX40mA
Interior Resistance: 100ohm
Output: 2V at 20mA / 0.4V at 4mA
Conversion Accuracy: 0.5%
Cable Length: 1.5 m
Unit: mm
RVR-52A Optional Input Cables
Materials: (1)M3.5 Crimp Terminal, (2)Vinyl Coated Electrical Wire, (3)Connector
RPR-7101
Pulse Input Cable
Unit: mm
RVR-5203
4-20mA Probe Cable
Maximum Current Input: MAX40mA
Interior Resistance: 100ohm
Output: 2V at 20mA / 0.4V at 4mA
Conversion Accuracy:0.5%
Cable Length: 1.5 m
Unit: mm
Sensor Extension Cables
Materials: (1)Vinyl Coated Electrical Wire
TR-2C30 (for RTR-52/52A)
Sensor Extension Cable
Materials: 1.Vinyl Coated Electrical Wire
Only one cable per sensor. When using the extension cable there will be a +0.3°C at normal temperature and at -50°Ca gap of +0.5°C may occur.
Unit: mm
VR-2C10 (for RVR-52A)
Sensor Extension Cable
Unit: mm
Options For RTR-51/51A/52/52A/52Pt/53/53A, RVR-52A
TR-05K3
Wall Attachment
Operational Environment Temp:
-40 to 80°C
For RTR-5/RVR-5/TR-5
*Cracks may develop if exposed to strong impact at temperatures of -30°C or less.
Unit: mm
TR-05K3L
Wall Attachment
Operational Environment Temp:
-40 to 80°C
For RTR-5L/RVR-5L/RTR-5/RVR-5/TR-5/RTR-05A1/RTR-05B
*Cracks may develop if exposed to strong impact at temperatures of -30°C or less.
Unit: mm
TR-00P1 : Maintenance Set
Rubber Packing x 1, Silica Gel x1, Double-sided Adhesive Tape x 1, Lock Screw x 2
TR-11P2 : Low-Temperature Battery Set
Lithium battery SAFT(LS14250) x 1, Tube x 1, Maintenance Set x 1
RTR-05A1 : External Power Adaptor Kit
Voltage Input: DC6V
Back-up Power: Ni-MH Battery (In case of power loss)
Back-up Time : 1 days
Charging Method : Trickle Charge
Operating Temperature : 0 to 60°C
Waterproof Capacity : None
Weight : about 37g (without AC Adaptor)
Kit Contents : External Power Adaptor x1
AC Adaptor (AD-0604) x1 or AC Adaptor (AD-0638 (*1) ) x 1
Attachment hook x1
Rubber Packing x1 (for back of main unit)
Rubber Packing (small) x1 (for AC Adaptor jack)
Silica Gel Pack (drying agent) x1
Double-sided Adhesive Tape x1(for fastening silica gel)
Screws x 2 (extras for fastening back of main unit)
(*1)AD-0638:Contact your local authorized representative.
Unit: mm
RTR-05A2 ( for U.S. only )
This is a model without an AC adaptor of RTR-05A1.
For details, contact your local authorized representative.
RTR-05B1 : Large Capacity Battery Adaptor Kit
Power: Lithium Battery x1 (LS26500) (*1)
Battery Life: about 2 years and 6 months (Monitoring at 1 minute interval = about 20 months) (*2)
Waterproof Capability: Splash proof
Operating Temperature: -40 to 80°C (*3)
Weight: about 75g (including lithium battery)
Kit Contents: Large Capacity Battery Adaptor x1
Attachment hook x1
Rubber Packing x1 (for back of main unit)
Silica Gel Pack (drying agent) x1
Double-sided Adhesive Tape x1(for fastening silica gel)
Screws x2 (extras for fastening back of main unit)
NOTE:
(*1)When using RTR-05B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized representative.
(*2) Battery Life varies depending on measuring environment, recording interval, transmission frequency, and ambient temperature. The battery life estimated here is calculated using a new battery under normal operating conditions and in no way should be understood as a guarantee of battery life.
(*3) Operating temperature depends on the specifications for the data logger being used.

Unit: mm